|
AUTODOCK GmbH
ligand 31drh1-100-176 (va-0) Ligand 31drh1 100 176 (Va 0), supplied by AUTODOCK GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/ligand+31drh1+100+176++va+0+/pmc07452031-159-6-14 Average 90 stars, based on 1 article reviews
ligand 31drh1-100-176 (va-0) - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
PlasticsOne inc
anchor screws plastics one 0–80x3/32 in Anchor Screws Plastics One 0–80x3/32 In, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/anchor+screws/pmc01373667-74-5-7 Average 90 stars, based on 1 article reviews
anchor screws plastics one 0–80x3/32 in - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
DuPont de Nemours
ethylene vinyl acetate copolymer grafted with maleic anhydride Ethylene Vinyl Acetate Copolymer Grafted With Maleic Anhydride, supplied by DuPont de Nemours, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/maleic+anhydride+grafted+polymer/us08048519-89-10-21 Average 90 stars, based on 1 article reviews
ethylene vinyl acetate copolymer grafted with maleic anhydride - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
PlasticsOne inc
emg patch electrodes Emg Patch Electrodes, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/emg+patch+electrodes/pmc02864878-84-36-39 Average 90 stars, based on 1 article reviews
emg patch electrodes - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
PlasticsOne inc
bipolar stimulating electrodes plastics one, roanoke, va, 0.15-mm diameter, stainless steel, and bipolar Bipolar Stimulating Electrodes Plastics One, Roanoke, Va, 0.15 Mm Diameter, Stainless Steel, And Bipolar, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/bipolar+stimulating+electrode/pmc03235504-70-0-3 Average 90 stars, based on 1 article reviews
bipolar stimulating electrodes plastics one, roanoke, va, 0.15-mm diameter, stainless steel, and bipolar - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
CHEMetrics
cod test kit, 0–1500 ppm (hr) mercury-free Cod Test Kit, 0–1500 Ppm (Hr) Mercury Free, supplied by CHEMetrics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/hydrogen+peroxide+chemets+++kit++0+++1+++1+++10+ppm+/pmc07528165-103-16-22 Average 90 stars, based on 1 article reviews
cod test kit, 0–1500 ppm (hr) mercury-free - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Cell Signaling Technology Inc
va 0 1045 0 0170 c d p 0 001 Va 0 1045 0 0170 C D P 0 001, supplied by Cell Signaling Technology Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/CUL3+Rabbit+mAb/10__1097_slash_ijg__0000000000001024-68-16-32 Average 94 stars, based on 1 article reviews
va 0 1045 0 0170 c d p 0 001 - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
scanalytics inc
iplab software Iplab Software, supplied by scanalytics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/iplab+software/10__1155_slash_2016_slash_8237029-88-13-21 Average 90 stars, based on 1 article reviews
iplab software - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Merck KGaA
millicell-24 cell culture plates Millicell 24 Cell Culture Plates, supplied by Merck KGaA, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/millicell+24+well+cell+culture+plate/pm34431664-651-7-11 Average 90 stars, based on 1 article reviews
millicell-24 cell culture plates - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
FUJIFILM
c-0 (va-044 C 0 (Va 044, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/va+044/pmc03014443-145-8-14 Average 90 stars, based on 1 article reviews
c-0 (va-044 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
ActiGraph llc
va counts per 5 s Va Counts Per 5 S, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/vm+counts+per+5+s/pmc04362848-215-61-63 Average 90 stars, based on 1 article reviews
va counts per 5 s - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
va-lcp screws at 0 ![]() Va Lcp Screws At 0, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/flow+cytometry+software+(isort+automated+cell+sorter%2C+va%2E0/va+lcp/pmc09358524-105-4-2 Average 90 stars, based on 1 article reviews
va-lcp screws at 0 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Annals of Translational Medicine
Article Title: Ability of modern proximal tibial lateral plates to capture posterolateral tibial plateau fracture fragments
doi: 10.21037/atm-22-750
Figure Lengend Snippet: Comparison of the material objects and the models for different plates. According to the respective manufacturer’s published data and precise physical measurement, the different four proximal tibial lateral plates were modeled accurately. (A) The 3.5 mm LCP ® Proximal Tibial Plate (DePuy Synthes). (B) The 3.5 mm VA-LCP ® Proximal Tibial Plate System (DePuy Synthes). (C) Periarticular Proximal Tibial Locking Plate (Zimmer). (D) Proximal Tibial Plating System (Biomet). LCP, locking compression plates; VA-LCP, variable angle locking compression plate.
Article Snippet: When the
Techniques:
Journal: Annals of Translational Medicine
Article Title: Ability of modern proximal tibial lateral plates to capture posterolateral tibial plateau fracture fragments
doi: 10.21037/atm-22-750
Figure Lengend Snippet: Fixation effectiveness of different plates
Article Snippet: When the
Techniques:
Journal: Annals of Translational Medicine
Article Title: Ability of modern proximal tibial lateral plates to capture posterolateral tibial plateau fracture fragments
doi: 10.21037/atm-22-750
Figure Lengend Snippet: 3D fracture maps of the uncaptured fragments for different internal fixations in oblique, axial, coronal and sagittal views: (A) the DePuy Synthes LCP; (B) the DePuy Synthes VA-LCP (at 0°); (C) the DePuy Synthes VA-LCP (at 0–15°); (D) the Zimmer plate; (E) the Biomet plate (at 0°); (F) the Biomet plate (at 0–25°). The uncaptured fragments were superimposed and represented in the gray zones. Darker colors represent a higher frequency of uncaptured areas. LCP, locking compression plates; VA-LCP, variable angle locking compression plate.
Article Snippet: When the
Techniques:
Journal: Annals of Translational Medicine
Article Title: Ability of modern proximal tibial lateral plates to capture posterolateral tibial plateau fracture fragments
doi: 10.21037/atm-22-750
Figure Lengend Snippet: Heat maps of the uncaptured fragments for different internal fixations in oblique, axial, coronal and sagittal views: (A) the DePuy Synthes LCP; (B) the DePuy Synthes VA-LCP (at 0°); (C) the DePuy Synthes VA-LCP (at 0–15°); (D) the Zimmer plate; (E) the Biomet plate (at 0°); (F) the Biomet plate (at 0–25°). Heat maps illustrated high and low densities of uncaptured locations. In axial views, the red arrow represents the range of the high-frequency area of uncaptured fragments and the blue arrow represents the range of the whole area of uncaptured fragments. The percentage indicates the proportion of the AP distance in the area to the total width of the lateral plateau. The fibula is shown for anatomical orientation. Fibular fractures were present in some cases but were not drawn. LCP, locking compression plates; VA-LCP, variable angle locking compression plate; AP, anteroposterior.
Article Snippet: When the
Techniques:
Journal: Annals of Translational Medicine
Article Title: Ability of modern proximal tibial lateral plates to capture posterolateral tibial plateau fracture fragments
doi: 10.21037/atm-22-750
Figure Lengend Snippet: The distribution of 3rd and 4th raft screws by the angle when using a variable manner. (A) The DePuy Synthes VA-LCP allows for variable screws with a cone of angulation of 15°. (B) The Biomet plate allows for variable screws with a cone of angulation of 25°. VA-LCP, variable angle locking compression plate.
Article Snippet: When the
Techniques: